SYMPTOMS |
PROBABLE CAUSES
|
RECOMMENDED
ACTION |
1.
Jets do not operate. |
A.
Pump not on |
A.
Turn on pump. |
B.
Jet flow–valve not opening. |
B.
Check for loose connections or wires leading from jet flow–valve
to auxiliary control. Replace jet flow–valve or auxiliary circuit
board as necessary. Refer to installer/dealer. |
C.
Pillow not in place. |
C.
Ensure that pillow is properly attached to jet. |
D.
Faulty reed switch. |
D.
Check reed switch wiring and connections leading from jet
to auxiliary control. Replace reed switch or auxiliary circuit
board as necessary. Refer to installer/dealer. |
E.
Faulty actuator switch. |
E.
Replace jet actuator. Refer to installer/dealer. |
F.
Power from pump to auxiliary control is off. |
F.
Check for loose connections or wires leading from pump
to auxiliary control. Refer to installer/dealer. |
G.
Jet line is blocked. |
G.
Disconnect jet line hoses, and remove blockage. Refer to
installer/dealer. |
H.
Switch wire from either auxiliary control to pump, or from
switch(es) to auxiliary control is disconnected. |
H.
Reconnect or replace switch wire(s) that use(s) modular
plug(s). Refer to installer/dealer. |
2.
Jets do not pulse. |
A.
Faulty pulse cannister. |
A.
Check for loose connections or wires leading from pulse
cannister to auxiliary control. Replace pulse cannister or auxiliary
circuit board as necessary. Refer to installer/dealer. |
B.
Faulty switch. |
B.
Replace switch. Refer to installer/dealer. |
C.
Switch wire from either auxiliary control to pump, or from
switch(es) to auxiliary control is disconnected. |
C.
Reconnect or replace switch wire(s) that use(s) modular
plug(s). Refer to installer/dealer. |